附件详情
-
一、 施工监测目的和项目概要...............................................................1
-
1.1 监测目的.........................................................................................1
-
1.2项目概要..........................................................................................1
-
二、监控量测系统设计..............................................................................3
-
2.1 监控量测设计依据.........................................................................3
-
2.2 监控量测设计原则.........................................................................3
-
2.3 监测项目.........................................................................................4
-
三、监测项目实施细则及监测频率..........................................................5
-
3.1桩顶水平位移监测实施细则..........................................................5
-
3.2 桩体变形监测实施细则.................................................................5
-
3.3 边坡土体水平位移监测实施细则.................................................6
-
3.4地表沉降及裂缝监测实施细则......................................................7
-
3.5土压力监测实施细则......................................................................8
-
3.6锚索轴力测量实施细则..................................................................9
-
3.7钢筋内力监测实施细则................................................................10
-
3.8地表建筑沉降及倾斜监测实施细则............................................11
-
四、监测控制标准、警戒值....................................................................12
-
4.1 监测控制标准...............................................................................12
-
4.2 警戒值...........................................................................................12
-
五 监测点和数量......................................................................................12
-
5.1 一般要求.......................................................................................12
-
5.2 测点的布置原则...........................................................................13
-
六、监控量测数据处理及信息反馈........................................................14
-
6.1外业观测值和记事项目................................................................14
-
6.2观测结果........................................................................................14
-
6.3 现场的监测资料要求...................................................................14
-
6.4
基坑工程
阶段性监测报告要求...................................................14
-
6.5 基坑工程监测总结报告内容.......................................................15
-
6.6应急措施........................................................................................15
-
七、监测保证措施和管理体系................................................................15
-
7.1保证措施........................................................................................15
-
7.2管理体系........................................................................................15
-
八、附图....................................................................................................16
附件详情
二、监控量测系统设计
第一:确切地预报破坏和变形等未来的动态,对设计参数和施工流程加以监控,以便及时掌握围岩动态而采取适当的措施(如预估最终位移值、根据监控基准调整、修改开挖和支护的顺序和时机等)…………
3.2 桩体变形监测实施细则
(2)监测实施方法:测斜管为外径70mm、内径66mm内壁有十字滑槽的PVC管,管长与相应桩等深,固定在钢筋笼上随之一起埋入围护桩体中。安装测斜管时,其一对槽口必须与基坑边线垂直,上下管口用盖子密封,安装完成后立即灌注清水,防止泥浆渗入管内…………
3.3 边坡土体水平位移监测实施细则
每次量测后应绘制位移—历时曲线,孔深—位移曲线。当水平位移速率突然过分增大是一种报警信号,收到报警信号后,应立即对各种量测信息进行综合分析,判断施工中出现了什么问题,并及时采取保证施工安全的对策…………
3.4地表沉降及裂缝监测实施细则
c、测量方法:观测方法采用精密水准测量方法。基点和附近水准点联测取得初始高程。观测时各项限差宜严格控制,每测点读数高差不宜超过0.3mm,对不在水准路线上的观测点,一个测站不宜超过3个,超过时应重读后视点读数,以作核对…………
3.6锚索轴力测量实施细则
锚索测力计安装在张拉端或锚固端,安装时钢绞线或锚索从测力计的中心穿过,测力计位于钢垫板和锚具之间,整个张拉过程采用油压表控制加载,分级张拉,拉力达到设计值时进行锁定(要防止锚索计偏心受力)…………
共19页
锚索测力计的安装示意图
钢筋计、土压力盒布置示意图
建筑物沉降测点示意图